2010-08-11

FLOWLINE LEVEL CONTROL INNOVATION


 LEVEL CONTROL INNOVATION 



EchoPod® DL24 3.0m , DL34 5.5m Multi-Function Ultrasonic Level Transmitter, Switch & Controller with (4) Relays
Description
The general purpose, ultrasonic sensor provides non-contact level detection up to 18.0' (5.5m) with 4 SPST 60 VA 1A relays and a two-wire 4-20 mA level measurement output. Each relay can be configured on a single set point alarm or latched on two sets for automatic fill or empty in simplex or duplex control modes with fail-safe logic. The embedded controller can replace external control hardware. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. EchoPod is broadly selected for day tanks, sumps, IBC totes, lift stations and mini-bulk storage applications.

Specification
Range:
4" to 8.2' (2.5m)
Signal output: 4-20 mA, two-wire
Contact type: (4) SPST relays 1A
Enclosure rating: Type 6P
Process mount: 1" NPT (1" G)

EchoPod® DL14 1.25m Multi-Function Ultrasonic Level Transmitter, Switch Controller

Description
The general purpose, ultrasonic sensor provides non-contact level detection up to 49.2" (1.25m) with 4 SPST 60 VA 1A relays and a two-wire 4-20 mA level measurement output. Each relay can be configured on a single set point alarm or latched on two sets for automatic fill or empty in simplex or duplex control modes with fail-safe logic. The embedded controller can replace external control hardware. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. EchoPod is broadly selected for small atmospheric day tank, skid or process vessel, lift station, IBC, drum and sump applications.

Specification
Range: 2" to 49.2" (1.25m)
Signal output: 4-20 mA, two-wire
Contact type: (4) SPST relays 1A
Enclosure rating: Type 6P
Process mount: 1" NPT (1" G)

EchoPod® DS14 1.25m Ultrasonic Level Switch & Controller with (4) Relays

Description
The general purpose, ultrasonic sensor provides non-contact level detection up to 49.2" (1.25m) with 4 SPST 60 VA 1A relays. The DS14 directly replaces contact switches connected to a PLC with 1-4 discrete points for easy design conversion or field retrofit. Each relay can be configured on a single set point alarm or latched on two sets for automatic fill or empty in simplex or duplex control modes with fail-safe logic. The embedded controller can replace external control hardware. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. The DS14 is broadly selected for small atmospheric tank, IBC, drum, skid or process vessel, lift station and sump applications. To configure EchoPod, download our free WebCal software and purchase one USB interface tool.
Specification
Range: 2" to 49.2" (1.25m)
Signal output: None
Contact type: (4) SPST relays 1A
Enclosure rating: Type 6P
Process mount: 1" NPT (1" G)

EchoPod® DX10 1.25m Ultrasonic Level Sensor with Voltage & Frequency Output


Description
The general purpose, DX10 ultrasonic sensor provides non-contact level measurement up to 49.2" (1.25m) with a 0-5 VDC, 0-10 VDC or 976-2000 Hz. frequency output. Select the voltage output to directly replace a contact measurement sensor connected to a PLC analog input. Select the frequency output to replace a contact measurement sensor or switch assembly, and eliminate the cost of an analog input card by connecting the DX10 to a PLC discrete input. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. The DX10 is broadly selected for small atmospheric tank, IBC, drum, skid or process vessel and sump applications. To configure EchoPod, download our free WebCal software and purchase one USB interface tool.
Specification
Range:
2" to 49.2" (1.25m)
Signal output: 0-5 V, 0-10 V, 976-2000 Hz
Contact type: None
Enclosure rating: Type 6P
Process mount: 1" NPT (1" G)
EchoPod® DL10 1.25m Ultrasonic Level Transmitter with 4-20 mA Output

Description
The general purpose, DL10 ultrasonic sensor provides non-contact level measurement up to 49.2" (1.25m) with a 4-20 mA output. The DL10 directly replaces contact measurement sensors connected to a PLC analog input card for easy design conversion or field retrofit. The two-wire, 4-20 mA output is ideal for longer signal distances up to 1000'. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. The DL10 is broadly selected for small atmospheric tank, IBC, drum, skid or process vessel and sump applications. To configure EchoPod, download our free WebCal software and purchase one USB interface tool.
Specification
Range:
2" to 49.2" (1.25m)
Signal output: 4-20 mA, two-wire
Contact type: None
Enclosure rating: Type 6P
Process mount: 1" NPT (1" G)
WebCal® Advanced Configuration Software
 

Description
WebCal software makes level measurement, switch and control configuration fast and easy. Take control of your level process with WebCal's intuitive interface, pre-programmed menus, tank set point graphics and custom wiring diagrams. To configure your WebCal enabled sensor, simply download your free copy of WebCal, create or open a saved configuration file, and click Write to Unit. Its that simple.

Specification
OS required:
Windows® XP & 2000
HD space required: 10 MB
RAM required: 256 MB
Ports required: (1) USB® 2.0

EchoSafe® XP88 XP89 Explosion Proof Two-Wire Ultrasonic Level Transmitte

Description
FM approved explosion proof for use in hazardous applications, the two-wire ultrasonic transmitter provides non-contact level measurement up to 32.8' or 10 m, and is well suited for challenging corrosive, slurry or waste liquids. Push button calibrated, the transmitter is typically selected for atmospheric bulk storage, day tank and waste sump applications located within a classified area. Media examples include sodium hypochlorite, diesel fuel and paint. The integral display and push button module enable fast and simple calibration.

Specification
Range:
8" to 32.8' (20cm to 10m)
Signal output: 4-20 mA, two-wire
Enclosure rating: Type 4, FM Class I, Div I Group A, B, C, D ; Class II, Div I Groups E, F, G ; Class II , Div I
Process mount: 2" NPT

Fluidwell™ XP 300400 Explosion Proof Level Meter


Description
CSA approved explosion proof for use in hazardous applications, the loop powered field meter displays engineering units connected in series with one 4-20 mA transmitter. The meter is typically selected for use with an explosion proof transmitter within a hazardous area. The windowed field enclosure is wall mounted for convenient viewing.

Specification
Display type: LCD, 5 1/2 digit
Sensor input: (1) 4-20 mA input
Contact type: None
Enclosure mount: Field

DeltaSpan™ LD30 Side Mounted Pressure Transmitter

Description
The general purpose two-wire pressure transmitter is offered in two termination packages and provides contact level measurement up to 69' or 21.1m of water column. Select the -S_01 for cable termination or the -S_11 for conduit termination with an integral junction box. The transmitter is best applied with clean liquid or gas media including water, oil and air. Application examples include irrigation equipment, pumping systems and compressors.


Specification
Range:
0 psi (0 bar) - 30 psi (2 bar) , 0-21.1 m.WC
Signal output: 4-20 mA two-wires
Enclosure rating: IP65
Cable length: 9' (3 m)

DeltaSpan™ LD31 IS, DL32 IS Submersible Pressure Transmitter

Description
The Intrinsiccally Safesubmersible two-wire pressure level transmitter is offered in two configurations for different liquid types and provides contact level measurement up to 46' (or 14m of water column. Select the LD31 for clean or relatively clean water, light weight oils and diluted chemical media. Application examples include ground water, ponds and wells. Select the LD32 for dirty, forming, sludge or slurry media. Application examples include sewer or storm pump lift stations, storage and treatment with surface foam or debris where ultrasonic cannot be applied.

Specification
Range:
0 psi (0 bar) - 20 psi (1.38 bar) , 0-14 m.WC
Signal output: 4-20 mA, two-wire
Enclosure rating: NEMA6 (IP67)
Cable length: 40' (12.2 m) or 60' (18.3 m)

Commander™ LI90 , Advanced Micro PLC Controller
Description
The general purpose controller has a graphic display with four 4-20 mA transmitter input channels and 6 programmable relays. Select from one of three run mode configurations including 1) Multi-tank with 4 inputs and 4 relays; or 2) Pump control with 1 input and 6 relays for lift stations including duplexing; or 3) Differential level with 2 inputs and 4 relays for municipal screen or rake control. Each relay can be configured on a single set point or latched on two set points for automatic fill or empty control. The LCD displays engineering units, relay and span status for each channel. The MicroSD card is ideal for data-logging storage and retrieval.

Specification
Display:
Backlit LCD
Input channel: (1) 4-20 mA
Contact type: (6) mechanical contact relays
Enclosure mount: 35 mm DIN rail

EchoSwitch® II LU74 LU77 LU78 Multi-Point Ultrasonic Level Switch
Description
The general purpose ultrasonic switch and controller provides non-contact level detection up to 24.6' (7.5 m) with 3 SPDT 60 VA 1A relays. EchoSwitch II features an LCD display with digital push button configuration. Each relay can be configured on a single set point alarm or latched on two set points for automatic fill or empty in simplex, duplex or triplex control modes with integral timer delay. The switch is well suited for a broad range of corrosive, waste and slurry type media. EchoSwitch II is broadly selected for atmospheric day tank, pump lift station and sump applications.

Specification
Range:
4" to 24.6' (10cm to 7.5m)
Configuration: Push button (no target required)
Contact type: (3) SPDT relays
Process mount: 2" NPT (2" G)

EchoSonic® II LU23 LU27 LU28 LU29 Two-Wires Ultrasonic Level Transmitte
Description
The general purpose two-wire ultrasonic transmitter provides non-contact level measurement up to 32.8' (10 m), and is well suited for challenging ultrapure, corrosive, slurry or waste liquids. The transmitter is broadly selected for atmospheric bulk storage, day tank, waste sump, process vessel, IBC tote, 55-gallon drum and waste sump applications. Media examples include acetic acid and resin.

Specification
Range:
4" to 32.8' (10cm to 10m)
Signal output: 4-20 mA, two-wire
Enclosure rating: Type 6P
Process mount: 1" / 2" NPT (1" / 2" G)

DataLoop™ II LI25  Intrinsically Safe Loop Powered Level Meter
Description

Offered in intrinsically safe and general purpose configurations, the loop powered panel meter displays engineering units connected in series with one 4-20 mA transmitter. Select the LI25-2001 meter for hazardous applications with an intrinsically safe level transmitter. Select the LI25-1001 meter for general purpose applications. For field mount installations, order the single or two meter NEMA box.

Specification
Display type: LCD, 5 digit
Sensor input: (1) 4-20 mA input
Contact type: None
Enclosure mount: 1/8 DIN, panel mount

DataView™ II LI55  Advanced Meter and Controller

Description

The general purpose meter displays engineering units with one 4-20 mA or 0-10 VDC transmitter input channel and is offered in three configurations with optional 2 or 4 relays, 4 or 8 set points and an isolated 4-20 mA repeater. Each relay can be configured on a single set point or latched on two set points for automatic fill or empty control including duplexing. For field mount installations, order the single or two meter NEMA box.

Specification
Display type: LED, 6 digit
Sensor input: (1) 4-20 mA input
Contact type: (4) 3A SPDT relays
Enclosure mount: 1/8 DIN, panel mount

TECHNICAL AND SALES SUPPORT


CORPORATE ADDRESS
VAASA (THAILAND) LIMITED
39/117 Moo 11, Srinakarin Rd., Bangkrew,Bangplee,Samutprakarn 10540 THAILAND
Tel: 662 753 6994
Fax: 662 753 6996
Hot-Line: 6681 935 2355
Email: vaasa@truemail.co.th
http://vaasathailand.blogspot.com


©1991-2010 VAASA (THAILAND) LIMITED
39/117 Moo 11, Srinakarin Rd., Bangkrew, Bangplee, Samutprakarn 10540 THAILAND
Phone: 662 753 6994 • Fax: 662 753 6996 • Hot-Line: 6681 935 2355

2 comments:

Icon Process Controls said...

This is really an important blog with many helpful information. I have been searching for a long time for this types of content. Keep up posting more and thanks for your great staff.

We offer wireless monitoring of local tank or streams using our battery operated talemetry tank level sensor. Thia sensor can be monitored inside plants or corporate campuses without running wires or conduit, saving significant cost. Level data can be displayed on mobile, laptop or other smart devices for viewing by authorized users. Transmitters will send every data via SMS, Email or Alarm to report to one or multiple receivers. More about telemetry tank level sensor

Monika said...

Thanks For sharing very helpful information
Vibrating Fork Point Level Switch for Liquids